Craven District Council

Skip Navigation

Craven District Council

Existing and Proposed Sections

The preferred electronic document types are .pdf’s although other formats can be submitted.

When required?

If any of the following apply:

  • a change in ground level;
  • the site is sloping;
  • a new building;
  • a track;
  • new opening(s);
  • new external staircase(s);
  • double glazing (listed building applications).

 

What is required?

Sections should

  • be drawn at a scale of 1:50 or 1:100
  • show a cross section(s) through the proposed building(s) and/or feature.
  • where a proposal involves a change in ground levels show both existing and finished levels.
  • for new buildings include:
    • existing site levels
    • finished floor levels and finished height
    • with levels related to a fixed datum point off site or shown in relation to adjoining buildings.
    • for sloping sites
    • show how proposals relate to existing ground levels or where ground levels would be modified.
    • for new tracks
    • show the method of construction and materials.
    • for new features e.g. external staircases, new openings or windows
    • a cross section through the proposed feature.